Avoiding Respiratory Complications Checklist
Train of Four monitor in every operating room (acceleromyography,
peripheral nerve stimulators)
Replacement batteries for monitor easily accessible
Tidal volume for ideal body weight reference cards available on each
anesthesia cart and online
Change default ventilator settings to:
400-500 cc tidal volume
Rate 10-12
PEEP ~5
Build Ideal Body Weight Calculations into electronic health record
Consider real-time alerting options for TV>10cc/kg, NMB reversal,
Train of Four monitoring, and recruitment maneuver reminders if
available
Check ASPIRE dashboard on monthly basis for performance review.
Target low performers with highest volume first for education
Utilize ARC Toolkit Presentation to promote best practice
Present performance review at departmental QI meetings