■ Diagnostic Imaging (measure exclusion)
■ Adenotonsillectomy
1. Adenoidectomy alone is not considered as risk factor
■ Tympanoplasty
● TRAN 01/02 (Blood Management)
○ Plan is to build separate TRAN 01/02 measures specific to pediatric patients in 2022
(10:30) MPOG Pediatric Data Review
● MPOG enables participants to view institutional comparison data on select measures at
collaborative meetings. Discussed if the pediatric subcommittee would be interested in a
performance review once per year
● (15:00) Majority of committee members are in favor of scheduling an MPOG peds data
review. Plan to host a blinded review of this data due to the heterogeneity of subcommittee
members.
Neuromuscular Blockade Measure Review
● (19:50) Train of Four Monitoring (NMB-01)
○ Reviewed current measure criteria and consensus was to continue measure as is. Some
further discussion surrounding how often sites use acceleromyography in pediatric
patients.
■ Brad Taicher, Duke: Only in older kids. Hard to get our device to function well in
younger cohort
■ Jacques Scharoun, Weill Cornell: Routine use
■ David Waisel, Yale: Do not use
■ Staphanie Kahntroff, University of Maryland: Do not use
○ Subcommittee recommendation: No change.
● (23:30) Reversal Administered (NMB-02)
○ Measure excludes patients <12y who receive defasciculating doses of non-depolarizing
NMB. This practice isn’t typically used in pediatrics but some community hospitals
around the country use defasciculating doses in adults despite limited evidence
○ Subcommittee recommendation: remove the time based reversal success criteria. Will
present recommendations to the quality committee on September 27, 2021.
○ (28:35) Performance Review/Discussion:
■ High variability in NMB-01 performance across MPOG sites for cases with
patients <18y.
■ Members expressed interest in the correlation of postoperative respiratory
complications and NMB-01 performance.
■ Discussion surrounding other reasons for NMB-01 performance variability:
1. TOF monitors may not be readily available in the OR at certain sites
2. Acceleromyography values are automatically recorded in Epic where as
TOF monitors require manual documentation
3. Michigan Medicine has seen increased compliance in TOF
documentation after focusing on NMB-01 as a department.
■ (33:50) Sugammadex vs. Neostigmine use across MPOG institutions in pediatric
patients < 18yo.